General
This specification covers the requirements for transmission
voltage, cable terminations for outdoor or indoor applications.
The termination design shall be G&W style PAT and suitable
for use on single conductor, cables through 245 kV. The terminations
shall be used on copper or aluminum conductor cable with extruded
insulation from 240-2500 mm2 (500 - 5000 kcmil).
Standards
and Ratings
The
terminations shall be designed, tested and built in accordance
with applicable sections of IEC 840, IEEE 48 for Class 1 terminations,
AEIC CS7 and AEIC CS6. The terminations shall be rated:
| Rated Voltage, kV (IEC) |
72.5 |
123 |
145 |
170 |
245 |
| Rated Voltage, kV (IEEE) |
69 |
115 |
138 |
161 |
230 |
| BIL, kV |
350 |
550 |
650 |
750 |
1050 |
Standard Components
• Standard creepage insulator
• Aluminum cap plate
• Mechanical shrink stress cone
• Dielectric fluid
• Tin-plated aluminum or unplated copper crimp-type
connector
• Threaded hood
• Aluminum corona shield
• Aluminum entrance housing and heat shrink jacket
seal, stand-off insulators (4) and galvanized steel mounting plate
• Cable preparation kit
Options
• Unplated copper or aluminum clamp-style 4 or pad style
8 aerial lug
• Drain valve
• Mounting plate
• Stainless steel suspension grip
• Wiping sleeve entrance
• Arcing horns (rod gap)
• Composite insulator
• Extra creepage insulator
• Brown porcelain insulator
• Tin plating or silver plating of copper connector
or aerial lugs
|