Load interrupting
with 40kA asymmetric momentary and fault interrupting to 12kA
symmetrical (18kA optional).
Switches combine linear puffer style load
break switching with electronically controlled vacuum interrupter
overcurrent protection in a deadfront, submersible construction.
All operating apparatus and cable entrances can be front accessible
permitting installation in confined areas. Front/back access
styles also available. Source side puffer switching incorporates
a visible break of all three phases. Submersible construction.
All operating apparatus and cable entrances can be front accessible
permitting installation in confined areas. Front/back access
styles also available. Source side puffer switching incorporates
a visible break of all three phases.
| Features:
|
 |
Operator Safety
— G&W Puffer Vacuum Interrupters are totally
sealed, deadfront and insulated with nonflammable, nontoxic
SF6 gas. Operators are spring assisted for positive quick-make,
quick-break operation. A trip-free mechanism permits interruption
independent of the operating handle if closing into a
fault. Viewing windows permit visible indication of interrupter
contact position. Enclosures provide tamper-resistant
construction with penta-head bolts and padlock provisions. |
 |
Minimal Maintenance
— No more routine inspections or dielectric testing
as with oil gear. No more contact contamination, rodent
problems or insulator maintenance as with air gear. A
periodic check of the gas pressure gauge is all that is
required. |
 |
Three
Phase Tripping — No more single phasing problems.
Simultaneous three phase tripping is available through
the electronics and with three phase operating handles
for manual operation and reset. |
 |
Protection
Curve Compatibility — No need to recoordinate
your distribution system. G&W solid state electronic
controls permit extremely accurate, consistent protection
curve characteristics compared to conventional fuses.
The exclusive controls can emulate the most common time
current curves (TCC) for power fuses, relays and fuse
links (oil fuse cutouts). Optional electronic packages
can provide ground trip, inrush restraint and adjustable
time delay capability. |
 |
User
Friendly Controls — Specific TCC characteristics
are easily field selectable. Controls permit individual
phase trip setting selection from twelve available levels. |
Applications:
G&W PVIs provide a direct replacement for power fused
air and vacuum-in-oil switchgear. Some ideal applications
include:
 |
Transformer
and Motor Protection — The three phase trip
feature and high continuous current capability make PVIs
ideal for protecting three phase motors and transformers. |
 |
Loop and Tap
Switching — Full 630A loop switching is accomplished
using the latest puffer technology. Tap switching through
630A and 12 to 18kA symmetric fault protection is accomplished
using resettable, electronically controlled vacuum interrupters.
The vacuum interrupters can also function as load break
switches. |
 |
Automatic
Transfer — For critical load applications,
PVIs can be supplied with an automatic transfer control
package to provide automatic transfer from one feeder
to another to minimize downtime. |
 |
Remote/SCADA
Control — G&W PVIs can be supplied with
motor actuators on both the line and load side providing
remote control capability. Various control packages including
portable DC controllers for onsite operation or complete
SCADA /RTU systems are available. |
 |
Metalclad
Switchgear Replacement — Front access PVI
designs provide switching alongside multiple vacuum interrupter
protected tap ways for an extremely compact, economical
alternative to metalclad or metal enclosed lineups. |
|