Switch Accessories and Options

Gas Pressure Gauge and Fill Valve (Standard)
The pressure gauge is a “GO-NO-GO” style which is color coded to simplify verification of proper operating conditions. A Schraeder type fill valve permits refilling in the field. The gauge and fill valve are made of brass for corrosion resistance. Both components are protected by a steel guard.

Viewing Windows provide a means to visibly verify switch contact position. Single phase or three phase contact viewing is available.

Padmount Enclosures (optional) are available if tamper-resistant or outdoor padmount construction is required around conventional vault style switchgear. Enclosures are made of 12 gauge mild steel with a corrosion-resistant green paint finish. Enclosures are typically shipped factory assembled.

Key Interlocks (optional) may be used as an added safety measure to prevent operation by unauthorized personnel or to assure safe coordination of energized equipment. Switches can be pro-vided with provisions only (two maximum per operating mechanism) or with keylocks factory installed. Specify locking scheme when ordering, i.e. lock in open, lock in closed or lock in both open and closed position. For keylocks to be coordinated with other equipment, manufacturer’s information must be provided.

Ground Lugs (optional) are bronze, eyebolt style for 4/0 maximum conductor cable.

Auxiliary Switches (optional) can be mounted adjacent to each external operating mechanism to permit remote indication of switching position. One N.O. and one N.C. form C contact is provided for wiring by the customer. A maximum of two auxiliary switches can be installed per operating mechanism.

Low SF6 Remote Monitoring Device (optional):
1) Low Pressure Warning Devices are factory set at 5 psig and permit remote indication of internal tank pressure. One N.O. and one N.C. form C contact is provided for wiring by the customer. Recommended for installations where ambient temperature does not fall below 0°F (-15°C).

2) SF6 Density Switches permit remote indication of internal tank gas density to assure proper pressure/temperature operating conditions. One N.O. and one N. C. form C contact is provided for wiring by the customer. Recommended for installations where ambient temperatures fall below 0°F (-15°C).

3) Temperature compensated gas density gauges measure internal tank gas density for maximum precision of switch operating pressure.  The gauge is color coded to simplify reading by operating personnel.

3-1/C, 600A Quik-Change Disconnectable Bushings
Cable entrance bushings can be damaged at any time due to improper handling, accidental shifting during shipment, elbow failure or even normal wear and tear. In the case of SF6 gas insulated switches where the tank is totally welded, conventional bushing replacement means sending the switch back to the factory for repair. G&W’s exclusive Quik-Change Disconnectable Bushing permits quick, easy field replacement without having to open the switch tank.

3-1/C, 600A Apparatus Bushings
Bushings are designed to ANSI/IEEE 386 standards with standard interface accepting conventional elbow style connectors and include an aluminum conductor with 5/8 "-11 aluminum threaded stud and aluminum single hole pad (elbows must be ordered separately). Copper studs and welded flange bushings are available. For bottom entry switches, recommended switch frame height is 42" for all voltages. Welded flange bushings are available.

3-1/C, 600A Voltage Sensing Apparatus Bushings

3-1/C, 200A Deepwell Bushings
Bushings are designed to ANSI/IEEE 386 standards with standard interface accepting deadbreak or load break inserts and conventional elbow connectors (inserts and elbows must be ordered separately). A copper conductor with copper single hole pad is standard. For bottom entry switches, recommended switch frame height is 42" for all voltages. Welded flange bushings are available.

3-1/C, 600A Apparatus Bushings
Welded Flange Style
Bushings are designed to ANSI/IEEE 386 standards with standard interface accepting conventional elbow style connectors. Bushings include a stainless steel flange and an aluminum conductor with 5/8 "-11 aluminum threaded stud. Elbows must be ordered separately. 200A deepwell welded flange available.

3-1/C, 600A Universal Bushings
The Universal Apparatus Bushing can be installed on virtually any type of padmount or submersible equipment providing a direct connect point for the U-Splice module. The combination U-Splice and apparatus bushing provides an extremely versatile interface between cable and equipment for easy connecting, disconnecting, and isolating of distribution cable circuits. Straight-in or 90 degree cable entry to equipment provides versatility important for applications with a minimum of space available. End caps for both bushing and splice module permit dead-ending of the cable and equipment for fast cable sectionalizing if required.

Universal bushings are designed to accept G&W universal bushing cable ends. An aluminum conductor and aluminum single hole pad is standard. For bottom entry switches, recommended switch frame height is 36" for all voltages. Hi-pot test kits are available.

NOTE: Universal bushings can accept up to two G&W Universal bushing cable ends per phase. For applications requiring this feature, consult factory.

Stainless steel tank
Stationary controls
Stainless steel enclosure
Low pressure warning device
SF6 density switch
Temperature compensated gas density gauge
Overpressure relief device
4/0 brass ground lug
Keylock provisions
Keylocks to lock in open position
Current transformers for current monitoring on automation schemes (600:5) (500:1) (1000:1)
Automatic transfer control
24VDC motor actuators
Auxiliary switches
Switch controls
Remote terminal units
Operations counter
200A deepwell bushings
200A deepwell bushings with deadbreak insert
600A apparatus bushings
600A Voltage Sensing bushings
600A Quik-Change apparatus bushings
600A Universal bushings (through 25kV)
Type 2 vacuum interrupter control
Type 3 vacuum interrupter control
External trip/power for vacuum interrupter control

 

 